LOCAL OPERATION
3-22
Tx power
The [Tx Power] key gives access to RF power measurement functions or associated functions.
Broad Band or Narrow Band power
The [Broad/Narrow] key selects which of the RF power measurement methods is operative. The
selected method is indicated on the display by the letters BB or NB to the right of the digital power
reading. The use of this facility is explained under Making measurements later in this chapter.
See page 3-27.
Directional Power
The [Dir Power] key displays the screen required for using the optional directional power and
VSWR accessories. The use of the Directional Power Head accessory is described in Appendix A
of this manual.
To leave this screen, press any of the blue MODE keys. The top level screen of that mode will be
displayed.
RF harmonic Analysis
The [Harmonc Analys] key activates the RF harmonic Analysis function. The right-hand side of
the screen shows five horizontal bar charts. The upper bar chart shows the power meter reading
and is the same as that shown on the other Tx TEST screens.
The four
HARMONICS bar charts, display the level of the 2nd, 3rd, 4th and 5th harmonics of the
carrier. The frequency range of the Service Monitor governs the number of harmonics of which
readings can be made.
The use of this facility is explained under Making measurements later in this chapter. See page
3-28.
Pressing the [Return] key will display the previously used Tx TEST screen with the Tx power
menu.
RF transient power Analysis
The [Trans Analys] key selects the RF Power
TRANSIENT ANALYSIS mode.
This mode displays a captured RF power profile of a transmitter against time. Triggering is
activated by the RF level passing a preset value. The signal is captured using a continually
updated, first in/first out, storage device. This allows the Service Monitor to show the power
profile both before and after the trigger point.
The use of this facility is explained under Making measurements later in this chapter. See page
3-29
Pressing the [Return] key will display the previously used Tx TEST screen with the top level
Tx TEST menu.
Occupied Bandwidth
The [Occ B/width] key is displayed if the option is enabled. It selects the RF Power
OCCUPIED
BANDWIDTH mode.
This mode provides a Spectrum Analyzer display of RF level against frequency, with markers to
indicate the extent of the bandwidth occupancy of the displayed signal, for the selected Occupied
Bandwidth Ratio.
The Occupied Bandwidth Ratio is variable in 0.1% steps within the range 90.0 to 99.9%.
The display has soft keys to allow selection of Display RF Reference Level, Occupied Bandwidth
Ratio, Test Set RF Generator ON/OFF, Display Center Frequency, Display Span and Display
Resolution Bandwidth.
The use of this facility is explained under Making measurements later in this chapter. See page
3-33.